Items : %s%s
AC Fans
Factory Lead Time
- 15 Weeks
- 16 Weeks
- 20 Weeks
Feature
- Temperature Sensor
Housing Material
- Aluminium
Material
- Aluminium
- Metal
- Plastic
Material - Blade
- Polybutylene Terephthalate (PBT)
Material - Frame
- Aluminum
Max Operating Temperature
- 158°C
- 176°C
Min Operating Temperature
- -40°C
- -4°C
- 14°C
Moisture Sensitivity Level (MSL)
- 1 (Unlimited)
Mount
- Flanges
Operating Temperature
- -40~158°F -40°C~70°C
- -4~176°F -20°C~80°C
- 14~149°F -10°C~65°C
- 14~158°F -10°C~70°C
- 14~176°F -10°C~80°C
Package / Case
- Axial
Packaging
- Box
Part Status
- Active
Published
- 2006
- 2008
- 2009
- 2010
Series
- 8000N
- OA109
- OA172AP
- OA172SAP
- OA172SAPL
- OA254
- OA80
Size / Dimension
- Rectangular/Rounded - 172mm Lx150mm H
- Round - 172mm Dia
- Round - 254mm Dia
- Square - 119.5mm Lx119.5mm H
- Square - 120mm Lx120mm H
- Square - 60mm Lx60mm H
- Square - 80mm Lx80mm H
Termination
- 2 Terminals
- 2 Wire Leads
Weight
- 1.1lbs 499.0g
- 1.2lbs 544.3g
Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Datasheet | Factory Lead Time | Mount | Material | Housing Material | Packaging | Series | Pbfree Code | Part Status | Moisture Sensitivity Level (MSL) | Termination | Max Operating Temperature | Min Operating Temperature | Color | Depth | Operating Supply Voltage | Diameter | Length | RoHS Status | Lead Free | Voltage - Rated | Current Rating | Radiation Hardening | Additional Feature | Package / Case | Max Supply Voltage | REACH SVHC | Min Supply Voltage | Frequency | Height | Width | Approval Agency | Outside Diameter | Weight | Operating Temperature | Size / Dimension | Voltage Range | Ratings | Voltage - Rated AC | Ingress Protection | Power Rating | Lead Length | Max Power Dissipation | Feature | Cable Length | Hole Diameter | Current Rating (Amps) | Mounting Hole Spacing | Construction | Lifetime @ Temp | Power Consumption | Air Flow | Power (Watts) | Material - Frame | Material - Blade | RPM | Bearing Type | Fan Type | Noise | Static Pressure | Thermal Support Device Type | Rated Power |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
A4E300-AS72-01 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Metal | A4E300 | Active | 1 (Unlimited) | 4 Wire Leads | Black | 230V | 300mm | ROHS3 Compliant | 230VAC | Axial | CCC, CE, EAC, UL | 3.7lbs 1.7kg | -13°C~122°C -25°C~50°C | Round - 300mm Dia | IP44 | Capacitor, Thermal Overload Protection (TOP) | 450mm | 0.420A | 96W | 1059 CFM | 96.0W | Steel, Polypropylene (PP) Coating | 1500 RPM | Ball | Tubeaxial | 0.241 in H2O (60.0 Pa) | |||||||||||||||||||||||||||||||||||
![]() |
QR06A-2/106350 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | Flanges | QR06 | Obsolete | 1 (Unlimited) | Terminal Block | 158mm | RoHS Compliant | Lead Free | 230VAC | No | 5.06kHz | 88mm | 6lbs 2.7kg | Rectangular - 575mm Lx88mm H 88mm Dia | 41W | 41W | 190.0 CFM (5.32m3/min) | 41.00W | Steel | Aluminum | Ball | Blower, Cross Flow | 55.0 dB(A) | ||||||||||||||||||||||||||||||||||||||||
![]() |
W2K121-AA01-39 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | W2K121 | Obsolete | 1 (Unlimited) | 2 Terminals | 127mm | RoHS Compliant | Lead Free | 230VAC | No | Axial | 38mm | CSA, UL, VDE | 1.3lbs 589.7g | Square - 127mm Lx127mm H | 17W | 17W | 121.0 CFM (3.39m3/min) | 17.00W | Metal | Polyamide (PA), Nylon | Sintec | Tubeaxial | 47.0 dB(A) | ||||||||||||||||||||||||||||||||||||||||
![]() |
D2E146-HR29-83 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | D2E146 | Active | Not Applicable | 6 Position Rectangular Connector | Non-RoHS Compliant | 115VAC | CE, CSA, VDE | -13~140°F -25°C~60°C | Rectangular/Rounded - 253mm Lx218mm H | IP20 | Capacitor, Thermal Overload Protector (TOP) | 1.40A | 160W | Polypropylene (PP) | Steel | 1000 RPM | Ball | Blower, Centrifugal | ||||||||||||||||||||||||||||||||||||||||||||||
![]() |
R3G220-RD53-03 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | External | Plastic | Green Tech RadiCal® R3G220RD | Active | 1 (Unlimited) | 2 Wire Leads | Black | 90mm | 230V | ROHS3 Compliant | 230VAC | No SVHC | UL | 3.2lbs 1.5kg | -13~113°F -25°C~45°C | Round - 252mm Dia | 200V~240VAC | IP54, Water Resistant | IP54 - Dust Protected, Water Resistant | 168W | 168W | Electronic Commutation (EC) | 450mm | 747.5 CFM (20.93m3/min) | Aluminum | Polyamide (PA), Nylon, Fiberglass Reinforced | 3230 RPM | Ball | Motorized Impellers | 69.0 dB(A) | ||||||||||||||||||||||||||||||||
![]() |
55410.91190 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | QLZ06 | Active | 1 (Unlimited) | 2 Terminals | RoHS Compliant | Lead Free | 115VAC | 60Hz | Rectangular - 260mm Lx83mm H 60mm Dia | 35W | 35W | 72.0 CFM (2.02m3/min) | 35.00W | Steel | Aluminum | Sleeve | Blower, Cross Flow | 50.0 dB(A) | AC BLOWER | ||||||||||||||||||||||||||||||||||||||||||
![]() |
R2E150-AN89-14 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | R2E150 | Active | Not Applicable | 4 Wire Leads with Splice Terminals | RoHS Compliant | 115VAC | CE, CSA, UL | 176°F 80°C | Round - 152mm Dia | IP44 | Capacitor, Thermal Overload Protector (TOP) | 0.300A | 33.00W | Steel | 2550 RPM | Ball | Motorized Impellers | |||||||||||||||||||||||||||||||||||||||||||||
![]() |
RG160-28/56S | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | Plastic | Steel | RG160 | Active | 1 (Unlimited) | 2 Wire Leads | 220mm | 230V | RoHS Compliant | Lead Free | 230VAC | No | Radial | No SVHC | 50Hz | 220mm | CE, CSA, UL, VDE | 3.8lbs 1.7kg | -22~158°F -30°C~70°C | Square - 220mm Lx220mm H | 230V | 47W | 325mm | 47W | 5.3 mm | 203 mm | 30000 Hrs @ 40°C | 47W | 118.9 CFM (3.33m3/min) | 47.00W | Plastic, Glass Filled | Plastic, Fiberglass Reinforced | 2750 RPM | Ball | Blower, Flatpak | 69.0 dB(A) | AC BLOWER | ||||||||||||||||||||||||
![]() |
A2D200-AI18-01 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | 20 Weeks | A2D200 | Active | Not Applicable | 7 Wire Leads with Splice Terminals | Non-RoHS Compliant | 400VAC | CCC, CE, EAC | -13~158°F -25°C~70°C | Round - 195mm Dia | IP44 | 0.130A | 530.1 CFM (14.84m3/min) | 70.0W | Steel | 2900 RPM | Ball | Tubeaxial, 3 Phase | 68.0 dB(A) | 0.562 in H2O (140.0 Pa) | ||||||||||||||||||||||||||||||||||||||||||||
![]() |
R2E190-AO74-91 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | 8 Weeks | R2E190 | Active | Not Applicable | Wire Leads | 115V | RoHS Compliant | Round - 190mm Dia | 75W | Capacitor, Thermal Overload Protector (TOP) | 365 CFM | Polyamide (PA), Nylon, Fiberglass Reinforced | Ball | Motorized Impellers | ||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
BF55462.40760 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | Metal | PBT | Active | Not Applicable | Connector | 115V | RoHS Compliant | 60Hz | 997.903214g | 115V | 41W | 105 CFM | Ball | |||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
W2S130-AA25-51 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | Aluminium | Metal | W2S130 | Active | 1 (Unlimited) | 2 Terminals | 80°C | 172mm | 115V | 150mm | RoHS Compliant | Lead Free | 115VAC | No | Axial | 5.06kHz | 55mm | CE, CSA, UL | 2.4lbs 1.1kg | Round - 150mm Dia | 38W | 38W | 41W | 225.0 CFM (6.30m3/min) | 38.00W | Aluminum | Steel | Ball | Tubeaxial | 52.0 dB(A) | AC FAN | ||||||||||||||||||||||||||||||
![]() |
G4E180-AB01-01 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | Aluminium | G4E180 | Active | 1 (Unlimited) | 2 Wire Leads | 125mm | RoHS Compliant | Lead Free | 230VAC | 640mA | No | 5.06kHz | CCC, CE | 8.2lbs 3.7kg | -40~176°F -40°C~80°C | Rectangular - 261mm Lx281mm H 180mm Dia | 145W | 145W | 0.640A | 350.0 CFM (9.80m3/min) | Aluminum | Steel | 1300 RPM | Ball | Blower, Centrifugal | 65.0 dB(A) | AC BLOWER | ||||||||||||||||||||||||||||||||||
![]() |
R2D225-AG02-10 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | R2D225 | Active | Not Applicable | Terminal Block | RoHS Compliant | 230/400VAC | CE, EAC | -13~167°F -25°C~75°C | Round - 250mm Dia | IP20 | Dual Voltage | 0.390/0.670A | 250W | 3000 RPM | Ball | Blower, Centrifugal | ||||||||||||||||||||||||||||||||||||||||||||||
![]() |
W2E143-AA15-01 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | Aluminium | Aluminium | W2E143 | Active | 1 (Unlimited) | 2 Terminals | 176°C | -40°C | 171.5mm | 115V | 172mm | 171.5mm | ROHS3 Compliant | 115VAC | 250mA | No | Axial | No SVHC | 5.06kHz | 172mm | 51.00mm | CCC, CE, CSA, GOST, UL, VDE | 172 mm | 2.1lbs 952.5g | -40~176°F -40°C~80°C | Round - 171.5mm Dia | 115V | 26W | 26W | 0.230A | 26W | 258.9 CFM (7.25m3/min) | 26.00W | Aluminum | Steel | 3300 RPM | Ball | Tubeaxial | 60.0 dB(A) | ||||||||||||||||||||||
![]() |
3850 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | 3000 | Active | 1 (Unlimited) | 2 Wire Leads | 92.5mm | RoHS Compliant | Lead Free | 230VAC | Axial | 50Hz | 38mm | CE, CSA, UL, VDE | 0.926lb 420.03g | 14~167°F -10°C~75°C | Square - 92mm Lx92mm H | 9W | 9W | 60000 Hrs @ 40°C | 28.8 CFM (0.806m3/min) | 9.00W | Metal | 1750 RPM | Sintec | Tubeaxial | 24.0 dB(A) | AC FAN | 9W | ||||||||||||||||||||||||||||||||||
![]() |
G2E140-AC13-42 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | Aluminium | Bulk | G2E140 | Active | 1 (Unlimited) | 2 Wire Leads | 40°C | 8.9mm | 115V | ROHS3 Compliant | Lead Free | 115VAC | No | 5.06kHz | 10.28mm | 7.5lbs 3.4kg | Round - 140mm Dia | 115V | 200W | 251.0 CFM (7.03m3/min) | 115W | Aluminum | Ball | Blower, Centrifugal | 67.0 dB(A) | AC BLOWER | |||||||||||||||||||||||||||||||||||
![]() |
W2E300-CC47-02 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | W2E300 | Active | Not Applicable | 4 Wire Leads with Splice Terminals | 397mm | RoHS Compliant | 230VAC | No | Axial | 5.06kHz | 90mm | CCC, CE, CSA, EAC, UL | -13~122°F -25°C~50°C | Round - 397mm Dia | IP44 | 140.1902MW | Capacitor, Thermal Overload Protector (TOP) | 0.880A | 200W | Steel | 2900 RPM | Ball | Tubeaxial | 0.602 in H2O (150.0 Pa) | AC FAN | ||||||||||||||||||||||||||||||||||||
![]() |
A2D250-AA02-18 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | 8 Weeks | Metal | A2D250 | Active | Not Applicable | 7 Wire Leads | 230V | RoHS Compliant | 230/400VAC | Axial | 50Hz | 250mm | CCC, CE, EAC | 2.2kg | -13~104°F -25°C~40°C | Round - 250mm Dia | 575mV | IP44 | 160W | Dual Voltage | 0.260/0.450A | 992 CFM | Steel | 2950 RPM | Ball | Tubeaxial, 3 Phase | 1.204 in H2O (300.0 Pa) | |||||||||||||||||||||||||||||||||||||
![]() |
R3G190-RD47-04 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | External | Green Tech RadiCal® R3G190RD | Active | 1 (Unlimited) | 2 Wire Leads | ROHS3 Compliant | 115VAC | No SVHC | UL | 3lbs 1.4kg | -13°C~122°C -25°C~50°C | Round - 190mm Dia | 100V~130VAC | IP54, Water Resistant | IP54 - Dust Protected, Water Resistant | 170W | Electronic Commutation (EC) | 553.3 CFM (15.49m3/min) | Aluminum | Polyamide (PA), Nylon, Fiberglass Reinforced | 4180 RPM | Ball | Motorized Impellers | 72.0 dB(A) | AC FAN | |||||||||||||||||||||||||||||||||||||
![]() |
RL90-18/50 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | Plastic | Steel | RL90 | Active | 1 (Unlimited) | 2 Wire Leads | 120.6mm | 230V | ROHS3 Compliant | Contains Lead | 230VAC | No | Radial | No SVHC | 50Hz | 121mm | 1.5lbs 680.4g | 14~122°F -10°C~50°C | Square - 121mm Lx121mm H | 230V | 20W | 310mm | 20W | 4.2 mm | 100.8 mm | 37500 Hrs @ 40°C | 20W | 23.5 CFM (0.658m3/min) | 20.00W | Plastic, Glass Filled | Plastic, Fiberglass Reinforced | 2450 RPM | Sleeve | Blower, Flatpak | 60.0 dB(A) | AC FAN | |||||||||||||||||||||||||
![]() |
S4E450-AP01-70 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | Flanges | S6E450A | Obsolete | 1 (Unlimited) | 2 Wire Leads | 522mm | RoHS Compliant | Lead Free | 230VAC | No | Axial | 5.06kHz | 129mm | CSA, UL, VDE | 11lbs 5kg | Round - 522mm Dia | 350W | 350W | 3735.0 CFM (104.58m3/min) | Metal | Ball | Tubeaxial | 75.0 dB(A) | ||||||||||||||||||||||||||||||||||||||||
![]() |
R3G220-RD21-03 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Wire | Aluminium | RadiCal® R3G220RD | yes | Active | 1 (Unlimited) | 2 Wire Leads | 220mm | ROHS3 Compliant | 230VAC | 1.4A | No | No SVHC | 92mm | UL | 220 mm | 3.2lbs 1.5kg | -13~113°F -25°C~45°C | Round - 252mm Dia | 200V~240VAC | IP54, Water Resistant | IP54 - Dust Protected, Water Resistant | 168W | 168W | 747.5 CFM (20.93m3/min) | Aluminum | Polyamide (PA), Nylon, Fiberglass Reinforced | 3230 RPM | Ball | Motorized Impellers | 69.0 dB(A) | |||||||||||||||||||||||||||||||
![]() |
A2D200-AA04-44 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Metal | A2D200 | Active | Not Applicable | 6 Wire Leads with Splice Terminals, 1 Ring Terminal | 280mm | RoHS Compliant | 230/400VAC | 150mA | Axial | 400V | No SVHC | 230V | 1.5kg | -13~176°F -25°C~80°C | Round - 195mm Dia | 315V | IP44 | Dual Voltage | 0.110/0.190A | 70W | 606 CFM | 65.0W | Steel | 3100 RPM | Ball | Tubeaxial, 3 Phase | |||||||||||||||||||||||||||||||||||
![]() |
K3G190-RD45-03 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Polyamide | Green Tech RadiCal® K3G190 | Active | 1 (Unlimited) | 7 Wire Leads | Black | 225mm | ROHS3 Compliant | 230VAC | CCC, CSA, EAC, UL | -13~140°F -25°C~60°C | Square - 266mm Lx266mm H | 200V~240VAC | IP54 - Dust Protected, Water Resistant | Capacitor, Electronic Commutation (EC), PWM Control, Speed Sensor (Tach), Thermal Overload Protector (TOP) | 450mm | 1.35A | 169W | Polyamide (PA), Nylon | Polyamide (PA), Nylon | 4120 RPM | Ball | Tubeaxial | 1.830 in H2O (455.0 Pa) | ||||||||||||||||||||||||||||||||||||||
![]() |
5958W | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | PBT | 5900 | Active | 1 (Unlimited) | 2 Wire Leads | 230V | ROHS3 Compliant | Lead Free | 230VAC | Axial | No SVHC | 60Hz | 127mm | 38mm | CCC, CE, CSA, UL, VDE | 1.3lbs 589.7g | -22~167°F -30°C~75°C | Square - 127mm Lx127mm H | 17W | 17W | 0.095A | 42500 Hrs @ 40°C | 17W | 121.2 CFM (3.39m3/min) | 17.00W | Metal | Polyamide (PA), Nylon, Fiberglass Reinforced | 3100 RPM | Ball | Tubeaxial | 46.0 dB(A) | 0.261 in H2O (65.0 Pa) | AC FAN | |||||||||||||||||||||||||||||
![]() |
55416.35070 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | QLN65 | Active | 1 (Unlimited) | Terminal Block | 60°C | RoHS Compliant | Lead Free | 240VAC | 5.06kHz | CSA, UL, VDE | Rectangular - 406mm Lx90mm H | 917mV | 56W | 58W | 144.0 ~ 155.0 CFM (4.03 ~ 4.34m3/min) | 58.0W | Steel | Aluminum | Sleeve | Blower, Cross Flow | 49.0 dB(A) | AC BLOWER | |||||||||||||||||||||||||||||||||||||||
![]() |
D2E133-DM47-01 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | Metal | D2E133 | Active | 1 (Unlimited) | 2 Wire Leads | 270mm | 230V | RoHS Compliant | Lead Free | 230VAC | 820mA | APPROVALS: VDE | 204 | 5.06kHz | 213mm | CCC, CE | 9.7lbs 4.4kg | -40~176°F -40°C~80°C | Rectangular - 204mm Lx213mm H 133mm Dia | 175.185kW | 195W | 5.5 mm | 0.820A | 254 mm | RADIAL | 353.0 CFM (9.88m3/min) | Steel | 2200 RPM | Ball | Blower, Centrifugal | 55.0 dB(A) | AC BLOWER | |||||||||||||||||||||||||||||
![]() |
S2E300-BP02-30 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 8 Weeks | Flanges | Bulk | S2E300 | Active | Not Applicable | 4 Wire Leads with Splice Terminals | 298mm | RoHS Compliant | 230VAC | No | Axial | 5.06kHz | 109mm | CCC, CE, EAC | -13~122°F -25°C~50°C | Round - 360mm Dia | IP44 | 230.25kW | Capacitor, Thermal Overload Protector (TOP) | 1.55A | 350W | Steel | 3000 RPM | Ball | Tubeaxial | 0.201 in H2O (50.0 Pa) | ||||||||||||||||||||||||||||||||||||
![]() |
R3G250-AV29-B1 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | R3G250 | Active | Not Applicable | Terminal Block | 230VAC | CCC, CE, EAC | -13~104°F -25°C~40°C | Round - 284mm Dia | 200V~277VAC | IP54 - Dust Protected, Water Resistant | Alarm, PWM Control, Thermal Overload Protector (TOP) | 3.30A | 1033.7 CFM (28.94m3/min) | 750W | Aluminum | 3450 RPM | Ball | Motorized Impellers |
-
A4E300-AS72-01 ebm-papst Inc.
Fan;AC;230V;300mm;Round;1059CFM;53dBA;90W;1500RPM;Leadwires
Price: 0.0000
RFQ -
-
-
-
R3G220-RD53-03 ebm-papst Inc.
EBM PAPST R3G220-RD53-03 Fan Blower, RadiCal, Backward Curved, RadiCal R3G220 Series, EC Centrifugal, 230 VAC, 220 mm, 92 mm
Price: 0.0000
RFQ -
55410.91190 ebm-papst Inc.
AC Blower Sleeve Bearing 115V 35W 60Hz 72CFM 50dB Flange Mount
Price: 0.0000
RFQ -
-
RG160-28/56S ebm-papst Inc.
EBM PAPST RG160-28/56SFan Blower, Centrifugal, RG160AC Series, 230 VAC, 220 mm, 56 mm, 118.9 cu.ft/min, 202 m/h
Price: 0.0000
RFQ -
-
-
-
-
-
-
-
-
-
-
-
R3G190-RD47-04 ebm-papst Inc.
EBM PAPST R3G190-RD47-04 CENTRIFUGAL FAN, 190MM X 90.7MM, 115VAC
Price: 0.0000
RFQ -
RL90-18/50 ebm-papst Inc.
EBM PAPST RL90-18/50Fan Blower, Centrifugal, Radial, Forward Curved, RL90AC Series, 230 VAC, 121 mm, 37 mm
Price: 0.0000
RFQ -
-
R3G220-RD21-03 ebm-papst Inc.
EBM PAPST R3G220-RD21-03 FAN, 220MM, 230VAC, EC, CENTRIFUGAL
Price: 0.0000
RFQ -
A2D200-AA04-44 ebm-papst Inc.
Fan;AC;230/400V;200x51;Round;606CFM;58dBA;60W;3300RPM;Leadwires
Price: 0.0000
RFQ -
K3G190-RD45-03 ebm-papst Inc.
AC Blower Ball Bearing 230V 1.35A 169W 50Hz/60Hz 4120RPM Flange Mount
Price: 0.0000
RFQ -
5958W ebm-papst Inc.
EBM PAPST 5958W Axial Fan, Tubeaxial, Square, Ball, 5900 Series, 230 VAC, 127 mm, 38 mm, 121.2 cu.ft/min
Price: 0.0000
RFQ -
-
-
S2E300-BP02-30 ebm-papst Inc.
AC Fan Ball Bearing 230V 1.1A/1.55A 230W/250W 50Hz/60Hz 2700RPM/3000RPM 2007.05CFM/2201.28CFM 73dB/76dB Flange Mount
Price: 0.0000
RFQ -