Call us: +86 0755-82563503

Currency: $ US Dollar

Items : %s%s

Cables & Wires

Cables management refers to the process of organizing and arranging electronic cables in a neat and efficient manner. This is important for several reasons, including improving the appearance of the electronic setup, reducing the risk of tripping hazards, and ensuring that cables are not damaged or tangled. Cables management can involve the use of various tools and accessories, such as cable ties, cable clips, and cable sleeves, to keep cables organized and secure. Proper cables management can also help to improve the performance and longevity of electronic components by reducing the risk of interference or damage caused by loose or tangled cables.

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Datasheet Factory Lead Time Packaging Published Series Part Status Moisture Sensitivity Level (MSL) Length RoHS Status Approval Agency Resistance Operating Temperature Ratings Shielding Voltage Insulation Material Number of Conductors Feature Connector Support Type Wire Gauge Conductor Material Jacket (Insulation) Material Jacket Color Jacket (Insulation) Diameter Jacket (Insulation) Thickness Construction Wire and Cable Name Usage Cable Type Shield Material Conductor Strand Shield Type Shield Coverage Conductor Insulation
2242C SL002 2242C SL002 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 5 Weeks Spool Active 1 (Unlimited) 500.0' 152.4m ROHS3 Compliant -20°C~80°C 300V 4 (2 Pair Twisted) Drain Wire 18 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Slate 0.333 (8.46mm) 0.0350 0.889mm Communication, Control Multi-Pair Aluminum 16/30 Foil 100% Poly-Vinyl Chloride (PVC)
78178 SL001 78178 SL001 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 10 Weeks Spool 2014 EcoCable® Mini Active 1 (Unlimited) 1000.0' 304.8m ROHS3 Compliant -40°C~80°C ISO 10993, UL Style 21460 300V 16 (8 Pair Twisted) Biological Compatibility, Drain Wire, Rip Cord WIRE AND CABLE 24 AWG Copper, Tinned Polyphenylene Ether, Modified (mPPE) Slate 0.251 (6.38mm) 0.0150 0.381mm Multi-Pair Aluminum 19/36 Foil 100% Polyphenylene Ether, Modified (mPPE)
541626YL002 541626YL002 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000
6429 SL001 6429 SL001 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 4 Weeks Spool 2006 Active 1 (Unlimited) 1000.0' 304.8m ROHS3 Compliant -20°C~105°C 300V 8 (4 Pair Twisted) Drain Wire WIRE AND CABLE 18 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Slate 0.438 (11.13mm) 0.0530 1.346mm Multi-Pair Aluminum 19/30 Foil 100% Poly-Vinyl Chloride (PVC)
422607 YL001 422607 YL001 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 7 Weeks Spool 2011 Active 1 (Unlimited) 1000.0' 304.8m ROHS3 Compliant -10°C~80°C UL Style 1061 300V 26 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Yellow 0.039 (0.99mm) 0.010 0.25mm Hook-Up 7/34
25493 BK005 25493 BK005 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 6 Weeks Spool 2008 Xtra-Guard® 2 Active 1 (Unlimited) 100.0' 30.5m ROHS3 Compliant -30°C~90°C ISO 10993, UL Style 20668 300V 6 (3 Pair Twisted) Biological Compatibility, Drain Wire, Rip Cord 24 AWG Copper, Tinned Polyurethane (PU) Black 0.228 (5.79mm) 0.0320 0.813mm Multi-Pair Aluminum 7/32 Foil 100% Poly-Vinyl Chloride (PVC)
3223 SL001 3223 SL001 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 5 Weeks Spool Active 1 (Unlimited) 1000.0' 304.8m ROHS3 Compliant -55°C~105°C 600V 4 WIRE AND CABLE 22 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Slate 0.203 (5.16mm) 0.0190 0.483mm Communication, Control Multi-Conductor Copper, Tinned 19/34 Braid 90% Poly-Vinyl Chloride (PVC)
5409/19SL002 5409/19SL002 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000
65304CY SL002 65304CY SL002 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 13 Weeks Spool Xtra-Guard® Flex Active 1 (Unlimited) 500.0' 152.4m ROHS3 Compliant UL Style 2587 600V 4 WIRE AND CABLE 2 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Slate 1.431 (36.35mm) 0.1100 2.794mm Multi-Conductor Copper, Tinned 1045/32 Braid 85% Poly-Vinyl Chloride (PVC)
390662 WH003 390662 WH003 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download Spool 2011 Obsolete 1 (Unlimited) 250.0' 76.2m -40°C~150°C ISO 10993 25kV Biological Compatibility 6 AWG Copper, Tinned Silicone Rubber White 0.337 (8.56mm) 0.062 1.57mm Hook-Up 133/27
6308 SL001 6308 SL001 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 5 Weeks Spool 2009 Active 1 (Unlimited) 1000.0' 304.8m ROHS3 Compliant -20°C~80°C UL Style 2464 300V 20 Drain Wire 24 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Slate 0.298 (7.57mm) 0.0320 0.813mm Multi-Conductor Aluminum 7/32 Foil 100% Poly-Vinyl Chloride (PVC)
6710 SL013 6710 SL013 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 7 Weeks Spool 2011 EcoWire® Active 1 (Unlimited) 5000' 1524.0m ROHS3 Compliant -40°C~105°C UL Style 11028 600V WIRE AND CABLE 28 AWG Copper, Tinned Polyphenylene Ether, Modified (mPPE) Slate 0.034 (0.86mm) 0.009 0.23mm Hook-Up 7/36
M3829 BK199 M3829 BK199 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download Spool Active 1 (Unlimited) 3000' 914.4m ROHS3 Compliant -25°C~90°C 600V 4 16 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Black 0.339 (8.61mm) 0.0470 1.194mm Multi-Conductor 7/0.0192 Poly-Vinyl Chloride (PVC)
6411SL002 6411SL002 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000
6713 BR001 6713 BR001 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 7 Weeks Spool EcoWire® Active 1 (Unlimited) 1000.0' 304.8m ROHS3 Compliant -40°C~105°C UL Style 11028 600V WIRE AND CABLE 22 AWG Copper, Tinned Polyphenylene Ether, Modified (mPPE) Brown 0.049 (1.24mm) 0.009 0.23mm Hook-Up 7/30
AZ201932 YL001 AZ201932 YL001 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 30 Weeks Spool 2011 MIL-DTL-22759/16 Active 1 (Unlimited) 1000.0' 304.8m ROHS3 Compliant -55°C~150°C 600V WIRE AND CABLE 20 AWG Copper, Tinned Ethylene Tetrafluoroethylene (ETFE) Yellow 0.060 (1.52mm) 0.011 0.28mm Hook-Up 19/32
6717SYL001 6717SYL001 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000
86401CY SL002 86401CY SL002 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 5 Weeks Spool 2001 Xtra-Guard® Flex Active 1 (Unlimited) 500.0' 152.4m ROHS3 Compliant ISO 10993, UL Style 2661 300V 2 (1 Pair Twisted) Biological Compatibility, Drain Wire WIRE AND CABLE 28 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Slate 0.186 (4.72mm) 0.0450 1.143mm Multi-Conductor Aluminum; Copper, Tinned 7/36 Foil, Braid 100%, 85% Poly-Vinyl Chloride (PVC)
77141 SL001 77141 SL001 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 7 Weeks Spool 2013 EcoCable® Active 1 (Unlimited) 1000.0' 304.8m ROHS3 Compliant -50°C~105°C ISO 10993 600V 2 Biological Compatibility WIRE AND CABLE 14 AWG Copper, Tinned Polyphenylene Ether, Modified (mPPE) Slate 0.264 (6.71mm) 0.0320 0.813mm Multi-Conductor Aluminum 41/30 Foil 100% Polyphenylene Ether, Modified (mPPE)
6422 SL002 6422 SL002 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 4 Weeks Spool 2006 Active 1 (Unlimited) 500.0' 152.4m ROHS3 Compliant -20°C~105°C 300V 22 (11 Pair Twisted) Drain Wire WIRE AND CABLE 22 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Slate 0.480 (12.19mm) 0.0530 1.346mm Multi-Pair Aluminum 7/28 Foil 100% Poly-Vinyl Chloride (PVC)
77233 SL199 77233 SL199 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 Spool EcoCable® Active 1 (Unlimited) ROHS3 Compliant -50°C~105°C ISO 10993 600V 4 Biological Compatibility 14 AWG Copper, Tinned Polyphenylene Ether, Modified (mPPE) Slate 0.329 (8.36mm) 0.0320 0.813mm Multi-Conductor Aluminum; Copper, Tinned 41/30 Foil, Braid 100% Polyphenylene Ether, Modified (mPPE)
5560/2C BK199 5560/2C BK199 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download Spool Xtra-Guard® 1 Active 1 (Unlimited) 1000.0' 304.8m ROHS3 Compliant -30°C~105°C UL Style 2343 300V 2 Drain Wire, Rip Cord WIRE AND CABLE 20 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Black 0.250 (6.35mm) 0.0630 1.600mm Multi-Conductor Aluminum 7/28 Foil 100% Poly-Vinyl Chloride (PVC)
3049GR005 3049GR005 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000
77011 SL005 77011 SL005 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 7 Weeks Spool 2012 EcoCable® Active 1 (Unlimited) 100.0' 30.5m ROHS3 Compliant -50°C~105°C ISO 10993 600V 9 Biological Compatibility WIRE AND CABLE 22 AWG Copper, Tinned Polyphenylene Ether, Modified (mPPE) Slate 0.251 (6.38mm) 0.0320 0.813mm Multi-Conductor 7/30 Polyphenylene Ether, Modified (mPPE)
M3431 SL002 M3431 SL002 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download Spool 2009 Active 1 (Unlimited) 500.0' 152.4m ROHS3 Compliant -20°C~80°C UL Style 2919 300V 50 (25 Pair Twisted) Drain Wire, Rip Cord 24 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Slate 0.608 (15.44mm) 0.0500 1.270mm Multi-Pair Aluminum; Copper, Tinned 7/32 Foil, Braid 100%, 65% Polypropylene (PP)
55010/12NA199 55010/12NA199 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000
80134 SL005 80134 SL005 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 7 Weeks Spool 2014 EcoFlex® PUR Active 1 (Unlimited) 100.0' 30.5m ROHS3 Compliant -50°C~90°C 600V 4 WIRE AND CABLE 18 AWG Copper, Tinned Polyurethane (PU) Slate 0.249 (6.32mm) 0.0319 0.810mm Multi-Conductor Copper, Tinned 41/34 Braid 85% Polyphenylene Ether (PPE)
3051 WV001 3051 WV001 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 7 Weeks Spool Active 1 (Unlimited) 1000.0' 304.8m ROHS3 Compliant CSA; UL 0.053Ohm -40°C~105°C ISO 10993, UL Style 1007/1569 NO 300V POLYVINYL CHLORIDE 1 Biological Compatibility WIRE AND CABLE 22 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) White, Violet Stripe 0.062 (1.57mm) 0.016 0.41mm STRANDED FLEXIBLE CORD AND FIXTURE WIRE Hook-Up 7/30
86105 SL001 86105 SL001 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download 4 Weeks Spool 2010 Xtra-Guard® Flex Active 1 (Unlimited) 1000.0' 304.8m ROHS3 Compliant ISO 10993, UL Style 2661 300V 5 Biological Compatibility 26 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Slate 0.191 (4.85mm) 0.0400 1.016mm Multi-Conductor 7/34 Poly-Vinyl Chloride (PVC)
PBM0001 YL002 PBM0001 YL002 Alpha Wire 0.0000
RFQ

Min: 1

Mult: 1

0.00000000 download Spool 2009 Obsolete 1 (Unlimited) 500.0' 152.4m -40°C~105°C UL Style 1283 600V 1/0 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Yellow 0.592 (15.04mm) 0.082 2.08mm Hook-Up 1045/30
Settings Need Help?
Top FAQ's

How can I quickly find answers to my questions?

Please visit the Help & Support area of our website to find information regarding ordering, shipping, delivery and more.

What is my Order Status?

Registered users can track orders from their account dropdown, or click here. *Order Status may take 12 hours to update after initial order is placed.

How do I return product?

Users can begin the returns process by starting with our Returns Page.

How do I find price and availability?

Quotes can be created by registered users in myLists.

How do I create a 'HK JDW' Account?

Visit the Registration Page and enter the required information. You will receive an email confirmation when your registration is complete.

United Kingdom/GBP Summary
Fast Shipping Fast Delivery

Orders are typically delivered to United Kingdom within 48 hours depending on location.

Free Shipping Free Shipping

Free delivery to United Kingdom on orders of £33 or more. A delivery charge of £12 will be billed on all orders less than £33.

Incoterms Incoterms

DDP (Duty and customs paid by HK JDW)

Payment Options Payment Types

Credit account for qualified institutions and businesses

Payment in Advance by Wire Transfer

Visa Mastercard American Express PayPal Apple Pay Google Pay

Marketplace Marketplace Product

More Products From Fully Authorized Partners

Average Time to Ship 1-3 Days, extra ship charges may apply. Please see product page, cart, and checkout for actual ship speed.

Incoterms: CPT (Duty, customs, and applicable VAT/Tax due at time of delivery)

For more information visit Help & Support